Mini-split line set size chart

The quick reference for ductless line set sizing — diameter by BTU and by brand, plus standard lengths. Want it done for you? Use the size calculator or look it up by brand.

Line set size by mini-split capacity

Line set diameter is set by your system's BTU rating. Match the pair below, then pick your length.

System sizeLine set (liquid × suction)Shop
9,000 BTU (¾ ton)1/4" × 3/8"Shop →
12,000 BTU (1 ton)1/4" × 1/2"Shop →
18,000 BTU (1.5 ton)1/4" × 1/2"Shop →
24,000 BTU (2 ton)3/8" × 5/8"Shop →
36,000 BTU (3 ton)3/8" × 5/8"Shop →
48,000 BTU (4 ton)3/8" × 5/8" (some 3/8" × 3/4")Shop →

Line set size by line size

Already know your diameters? Here's what each stocked pair fits.

Line setFits these systemsShop
1/4" × 3/8"9,000 BTUShop →
1/4" × 1/2"12,000–18,000 BTUShop →
3/8" × 5/8"24,000–36,000 BTU (and most 48,000 BTU)Shop →

Line set lengths

Length is set by the distance between your indoor head and outdoor condenser. Measure the full routing path — including bends and the drop — then round up to the next stocked length.

LengthBest for
15 ftShort runs — same room or just through the wall
25 ftThe most common length — typical wall-to-condenser runs
35 ftLonger runs, second-story, or units around a corner
50 ftMaximum reach — distant condenser placement

On pre-charged DIY systems, watch the maximum pre-charged length (often 25 ft) — longer runs may need refrigerant added by a pro.

Line set size by brand

Diameter is the same across brands for a given capacity — what changes is the connection. Pre-charged quick-connect systems (like MrCool DIY) use proprietary line sets; everything else is field-flared. Look up your exact brand →

These are the most common pairings; exact diameters and the maximum line length are always printed in your unit's installation manual — treat it as the final word.

Common questions

What size line set for a 12,000 BTU mini-split?

A 12,000 BTU (1-ton) mini-split typically uses a 1/4" liquid line and a 1/2" suction line — 1/4" × 1/2". Confirm against your unit's manual, since some 12,000 BTU models use 1/4" × 3/8".

What are the standard mini-split line set sizes?

The most common ductless line set sizes are 1/4" × 3/8", 1/4" × 1/2", and 3/8" × 5/8" (liquid × suction), sold in standard lengths of 15, 25, 35, and 50 feet.

This chart provides general guidance based on common mini-split line set sizing. Exact line diameters, connection types, and maximum line lengths vary by model — always verify against the manufacturer's installation manual before purchasing or installing.